Description
SS2 Float Switch Function: SS2 water level switch is applied in Air Conditioner systems to detect condensation water overflow; It detects blockage of air conditioning condensate water drain pipe and shuts down the system to prevent overflowing water from damaging floors, walls, and ceilings
Working Principle: the SS2 float switch can be connected to a VCC or thermostat line; It is an NC type (normally closed) switch: when no water overflows, the float stays at the bottom of the switch, the switch closes the loop and outputs an ON signal; When the water overflows, the buoyancy of the float rises, the trigger switch turns on, and the output OFF signal turns off
Specifications: switch type NC (normally closed), material PVC, operating temperature -20 - +80℃, wire length 5.8ft, switching voltage max; 200VDC; Switching current max; 1 A contact rating maximum 10W
Easy to Install: this float switch is easy to install, all you need to do is install the 3/ 4 adapter that comes with the AC float switch on the auxiliary drain outlet of the main panel and connect the 5.8ft of wire to VCC or thermostat wire
Easy to Clean: the transparent material allows you to see what's going on inside; The float switch is equipped with a removable cover; When you use it for some time, you can remove it for cleaning to ensure hygiene and normal function
Are you still worried about soaking your furniture due to condensation leaks when using your HVAC?
Then you absolutely need a float switch! Here are the specific installation steps for you:
INLINE INSTALLATION FOR (WALL) UNITS WITH VERTICAL DRAIN OUTLETS
It is recommended that this device be installed on the primary drain line between the pan outlet and P trap on wall units with vertical drain outlets. This will prevent the switch from shutting off the fan coil or activating the alarm circuit in the event condensate drips directly from the coil into the auxiliary pan outlet when the coil becomes dirty.
1. Disconnect power to unit at main panel and glue 5'' stub down from the primary pan outlet.
2. Glue 3/4'' Tee to bottom of stub with Tee stem horizontal and plumb.
3. Glue 3/4'' stub into horizontal outlet of Tee, insuring it is also plumb.
4. Ensure switch/plug assembly is inserted into 1'' inlet of PVC elbow so that float stem is at inside (bottom) of switch elbow. Float stem can be adjusted by threading it out of the plug assembly. DO NOT GLUE.
5. Glue a drain line with P trap onto the remaining outlet of Tee.
6. Connect the wires to VCC or the thermostat wires.
7. Test switch by lifting float with unit running. Unit should stop running if correctly connected.
8. Test all fittings and connections for plumbing leaks.
INSTALLATION FOR HORIZONTAL CEILING (PANCAKE) UNITS
NOTE: Primary drain (inline) is also recommended on horizontal ceiling (pancake) units as some flooding may occur if installed on auxiliary outlets, due to the closeness of the outlets to the top of the pan.
1. Glue 3/4'' stub to primary pan outlet.
2. Glue 3/4'' Tee onto stub with Tee stem positioned horizontally away from the unit and plumb.
3. Follow steps 3-9 under INLINE INSTALLATION FOR WALL UNITS, above.
Are you still worried about soaking your furniture due to condensation leaks when using your HVAC?
Then you absolutely need a float switch! Here are the specific installation steps for you:
INLINE INSTALLATION FOR (WALL) UNITS WITH VERTICAL DRAIN OUTLETS
It is recommended that this device be installed on the primary drain line between the pan outlet and P trap on wall units with vertical drain outlets. This will prevent the switch from shutting off the fan coil or activating the alarm circuit in the event condensate drips directly from the coil into the auxiliary pan outlet when the coil becomes dirty.
1. Disconnect power to unit at main panel and glue 5'' stub down from the primary pan outlet.
2. Glue 3/4'' Tee to bottom of stub with Tee stem horizontal and plumb.
3. Glue 3/4'' stub into horizontal outlet of Tee, insuring it is also plumb.
4. Ensure switch/plug assembly is inserted into 1'' inlet of PVC elbow so that float stem is at inside (bottom) of switch elbow. Float stem can be adjusted by threading it out of the plug assembly. DO NOT GLUE.
5. Glue a drain line with P trap onto the remaining outlet of Tee.
6. Connect the wires to VCC or the thermostat wires.
7. Test switch by lifting float with unit running. Unit should stop running if correctly connected.
8. Test all fittings and connections for plumbing leaks.
INSTALLATION FOR HORIZONTAL CEILING (PANCAKE) UNITS
NOTE: Primary drain (inline) is also recommended on horizontal ceiling (pancake) units as some flooding may occur if installed on auxiliary outlets, due to the closeness of the outlets to the top of the pan.
1. Glue 3/4'' stub to primary pan outlet.
2. Glue 3/4'' Tee onto stub with Tee stem positioned horizontally away from the unit and plumb.
3. Follow steps 3-9 under INLINE INSTALLATION FOR WALL UNITS, above.
Sold by
Amazon Warehouse
Official Amazon outlet for open-box & returned items
- Backed by Amazon's A-to-Z Guarantee
- 30-day return policy
- Ships from Amazon fulfillment centers
- Price verified on Amazon
Product Details
- SKU:
- awhd-us-b0d31p5fkn
- Model:
- DC-Feekoon-0450
- Country:
- US
- ASIN:
- B0D31P5FKN
Shopping Smarter
Common questions about buying open-box and refurbished.
Why buy refurbished or open-box?
Refurbished and open-box products offer the same performance as new at a fraction of the price. You're already saving $3 on this listing. They've been inspected, tested, and are ready to use — the only difference is the price tag. Buying refurbished also reduces electronic waste, extending product life cycles and keeping functional devices out of landfills.
What's the difference between open-box and refurbished?
Open-box products are customer returns that have been inspected and confirmed functional. They may show little to no use — often the item was returned simply because the buyer changed their mind. Refurbished products have been professionally repaired or restored by technicians, tested to meet or exceed manufacturer specifications, and sometimes come with a warranty. Both are a smart alternative to buying new.
Why use OpenBoxFox?
Finding refurbished deals is time-consuming — you'd have to check Amazon Warehouse, Reebelo, Dyson Outlet, and others separately for Feekoon products. OpenBoxFox aggregates these listings in one place, so you can compare and find the best deal without the legwork. We update pricing daily so you always see current availability and real savings.
Is it safe to buy refurbished?
Yes. Products listed on OpenBoxFox come from established retailers like Amazon, Reebelo, and Dyson — not unknown third-party sellers. Each retailer has buyer protection policies, return windows, and in some cases warranties. You get the price advantage of used goods with the purchase security of a known retailer.
More refurbished Feekoon deals
Updated daily from Amazon, Reebelo, and Dyson.